| Products |
Specifications |
| 646 Double Tilt holder |
It has the capability of up to +/-60° main tilt and up to +/-30° secondary tilt as well as excellent low background performance. |
| 925 Double Tilt Rotation holder |
Low vibration, minimum backlash and smooth operation are achieved with the titanium-geared cradle-drive mechanism. Precision gearing and jeweled bearings ensure smooth, continuous 360° rotation in both directions. |
| 670 Ultra High Tilt holder |
It is shaped to make optimum use of the space available inside the TEM. It is provided with large cutouts in the sides of the holder, and a new, low profile, specimen clamping system to minimize shadowing at high tilts. These features make it possible in many TEMs to obtain images at tilts as high as +/-80° in specimen areas as large as 2mm diameter. |
| 613 Single tilt holder/ 636 Double tilt holder |
TEM specimen cooling holders are mainly used to reduce contaimination due to carbon migration and to observe low-temperature in situ phase transformations. |
| CT3500 Cryo-transfer |
A complete cryotransfer system for TEM, including an ultra high resolution, nitrogen cryo-holder; a cryo workstation and a digital temperature controller. |
| CT3500TR Tilt-Rotate Cryo-transfer |
Including nitrogen cooled, single tilt specimen holder with specimen rotation, cooled shutter screwed insert, cryo-workstation, portable storage container for frozen specimens, tip protection sleeve with pump out fitting, digital controllers for temperature and rotation, tools. |
| 626 Cryo-transfer |
An integrated system with the features you want
in a cryostage: Excellent high-resolution performance, Robust and easy to use, Rapid, frost-free transfer, Precise temperature control, Innovative holder designs, Complete solutions for cryo-TEM |
| 630 High Tilt Tomography |
+/- 80° tilt capabilities in a liquid nitrogen cryotransfer stage: Three-dimensional electron microscopic imaging, or tomography, involves the reconstruction of individual objects from projection data collected over a large range of specimen tilts. |
| 910 Multispecimen holder |
Allowing two to three grids to be loaded into an interchangeable specimen cartridge that then fits into the tip of a cryotransfer holder. A stationary cryoshield protects samples from frost during transfer to the TEM. The 910 has a single tilt capability of up to ±50°, depending upon pole-piece configuration. |
| 915 Double Tilt holder |
The low background design and reduction of contamination and mass loss through maintenance of cryotemperatures facilitates high quality data collection for EDX, PEELS and GIF experiments. |
| UHRST 3500 |
Single tilt ultra high resolution nitrogen cooling holder |
| CHDT 3504 |
Double tilt high resolution nitrogen cooling holder |
| HC 3500 |
Single tilt heating/nitrogen cooling holder |
| Cryoplunge for cryofixation |
A cryo-fixation device to allow rapid freezing of thin film suspensions for cryo-TEM. |
| 655 Dry Pumping Station |
A completely self-contained, compact, light-weight, benchtop pumping station |
| 652 Double Tilt Heating Holder |
A specimen heating holder greatly increases the usefulness of TEMs in microstructural studies and allows the direct observation of phase changes, such as nucleation and growth and dissolution processes. |
| HHST 4004 |
Environmental Cell and Vacuum Transfer Holder for TEM |
| HCHST 3008 |
Single tilt high resolution helium cooling holder |
| ULTST |
Ultra low temperature single tilt helium cooling holder |
| HCHDT 3010 |
Double tilt high resolution helium cooling holder |
| ULTDT |
Ultra low temperature double tilt helium cooling holder |
| 677 FIB |
Multiple Specimen holder |
| In situ Probing TEM from Nanofactory Instruments AB* |
Nanofactory products incorporate miniaturised 3D movements, achieved using a patented piezo micropositioning device, to enable probe microscopy within the small dimensions of a TEM specimen holder tip. |
| STM Holder* |
• 3D nanoscale positioning of the probe
• electrical probing (tunneling, conductivity)
• I-V, I-Z plots - multi-mode STM imaging
• ST1000 Single-tilt TEM-STM system
• ST1500 Double-tilt TEM-STM system |
| TEM Indenter* |
• advanced control of probe motion for multiple manual and automated indentations
• real-time TEM imaging of sample and probe deformation
• SA2000N TEM-nanoindentation system |
| 654 |
Single Tilt Straining holder |
| 671 |
Single Tilt Cooling Straining holder |
| 672 |
Single Tilt Heating Straining holder |
| 912J |
High Tilt Tomography Holder for URP pole pieces |
| 912p |
High Tilt Tomography Holder for Ultra-Twin pole pieces |
| 914 |
Nitrogen Cooled Cryotransfer Tomography Holder |
| 916 |
Room Temperature Tomography Holder |
927 Dual orientation Tomography Holder
|
It allows the collection of tilt series with a fixed rotation of 90º between them. Rotation is by a simple flick lever at the back of the holder |
| Software: |
730 Tomography-Acquisition Software
|
3D tomography software works with Gatan's complete line of room-temperature & cryo-transfer Tomography Holders & Gatan Imaging Filters or digital TEM cameras on most TEMs |